MKF-PJS04 Hall / Potentiometer Effect, Dual Axis, Panel Mounted

$0.00

  • Ergonomics design on mobile application.
  • Contactless hall effect and long expect-life potentiometer optional.
  • Various handle, different number and location of button.
  • switches optional.
  • CAN bus output optional.

FREE QUOTE

Description

Electrical data

Potentiometer
Power supply <36Vdc
Resistance 2KΩ, 4KΩ, 5KΩ, 10KΩ
Electrical angle ±18°
Center voltage 48%~52%Vdc (Power supply)
Center tap angle ±2.5°
On-load voltage (max) 32Vdc
Power dissipation 0.25W ( 25°)
Hall
Power supply 5±0.5Vdc
Supply current <11mA (Each of hall )
Maximum allowable overload voltage 20Vdc
Reverse maximum allowable voltage -10Vdc
Output linearity tolerance <±4V
Directional switch
Load capacity 2mA@30Vdc (Resistance load)
Breakout angle ±3°~ 5°
Contact resistance <200Ω
With electronic amplifier
Power supply 18~36Vdc (U21~U24) 9~36Vdc
Power current consumption <20mA
Maximum output current 10mA
CAN BUS
Power supply 9~36Vdc
CAN Version CAN 2.0B
Protocol J1939
Connector 6 p-pin (Deutsch)
Microswitch
Load capacity 4A@30Vdc (Resistance load)
Expecting life 30 million times (Mechanical)  200 thousand times (Electrical)
Insulation resistance >100MΩ
Breakout angle ±3°~ 5°

 

Mechanical features

Travel angle ±20°
Operating type Spring return
Breakout force 7N
Operating force(max) 16N
Maximum allowable force >300N
Expecting life >2million cycles (Potentiometer) >5 million cycles (Hall effect)
Weight 475g (Without handle)

Environmental data

Operating Temperature -30℃~+70℃
Storage Temperature -40℃~+85℃
Protection level IP65 (Above the flange)
Video

Video

 

MSP Handle:

With 8 buttons: